E x p a n s i o n B o x I P A d d r e s s e s
The IP address of each expansion box is set by using the dip switches located on the Wago 750-871
PLC.
This is the layout of the IP addressing for the Ethernet expansion of the FLX conveying system. It
doubles the number of pumps from 20 to 40. It also doubles the number of loaders from 64 to 128
and the number of sources from 128 to 256. Each enclosure contains at least one PLC that deter-
mines the type of box it is. A unique IP address determines the type of box and the available I/O
determines if the box type is valid.
Box Type/Number
Pump Box 1
Pump Box 2
Pump Box 3
Pump Box 4
Pump Box 5
8 Loader Box 1
8 Loader Box 2
8 Loader Box 3
8 Loader Box 4
8 Loader Box 5
8 Loader Box 6
8 Loader Box 7
8 Loader Box 8
Combo Box 1
Loader 65 72 / Opt1 129 136 Opt2 161 168
Combo Box 2
Loader 73 80 / Opt1 137 144 Opt2 169 176
Combo Box 3
Loader 81 88 / Opt1 145 152 Opt2 177 184
Combo Box 4
Loader 89 96 / Opt1 153 160 Opt2 185 192
Combo Box 5
Loader 97 104 / Opt1 193 200 Opt2 225 232
Combo Box 6
Loader 105 112 / Opt1 201 208 Opt2 233 240
Combo Box 7
Loader 113 120 / Opt1 209 216 Opt2 241 248
Combo Box 8
Loader 121 128 / Opt1 217 224 Opt2 249 256
Source Box 1
Source Box 2
Source Box 3
Source Box 4
Source Box 5
Source Box 6
Source Box 7
Source Box 8
16 Loader Box 1
16 LoaderBox 2
16 Loader Box 3
16 Loader Box 4
Pumps 21 24
Pumps 25 28
Pumps 29 32
Pumps 33 36
Pumps 37 40
Loader 65 72
Loader 73 80
Loader 81 88
Loader 89 96
Loader 97 104
Loader 105 112
Loader 113 120
Loader 121 128
Opt1 129 136 Opt2 161 168
Opt1 137 144 Opt2 169 176
Opt1 145 152 Opt2 177 184
Opt1 153 160 Opt2 185 192
Opt1 193 200 Opt2 225 232
Opt1 201 208 Opt2 233 240
Opt1 209 216 Opt2 241 248
Opt1 217 224 Opt2 249 256
Loader 65 80
Loader 81 96
Loader 97 112
Loader 113 128
IP address
10.1.61.201
10.1.61.202
10.1.61.203
10.1.61.204
10.1.61.205
10.1.61.211
10.1.61.212
10.1.61.213
10.1.61.214
10.1.61.215
10.1.61.216
10.1.61.217
10.1.61.218
10.1.61.221
10.1.61.222
10.1.61.223
10.1.61.224
10.1.61.225
10.1.61.226
10.1.61.227
10.1.61.228
10.1.61.231
10.1.61.232
10.1.61.233
10.1.61.234
10.1.61.235
10.1.61.236
10.1.61.237
10.1.61.238
10.1.61.241
10.1.61.242
10.1.61.243
10.1.61.244
i
NOTE: The 4th octets
221-228 replace both
211-218 and 231-238. So
if you add 10.1.61.221 you
must not have 10.1.61.211
or 10.1.61.231.
i
NOTE: Each 16 Loader
box replaces 2 of the 8
Loader boxes and any
combo boxes associated
with these loaders.
i
NOTE: Each PLC has two
Ethernet ports so they can
be daisy chained together.
The chain length limit is
20 PLC including the main
PLCs. Do not connect the
last PLC's 2nd port back to
the switch. This will cause
the N-Tron switch to
crash.
A p p e n d i x l