LED
Description
Normal
State
Link
Link to a physi-
GREEN
cal network
MS
Indicates the
GREEN
state of the
node (Module
State)
NS
Indicates the
GREEN
state of the
node (Network
State)
Other States
OFF- Not connected to a network
Check cabling.
J
RED/GREEN FLASHING - Self test
RED - Controller indicates a not remediable error
Restart by turning power off and on again.
J
GREEN FLASHING - Controller is not yet configured
OFF - No system supply voltage
Check the supply voltage (24V and 0V).
J
RED/GREEN FLASHING - Self test
RED - Controller indicates a duplicate IP address on the
network
Use an IP address that is not used on the network.
J
Cycle power to controller.
J
RED FLASHING - Network connection time out
Restart by turning power off and on again.
J
GREEN FLASHING - No connection
OFF - No system supply voltage
Check the supply voltage (24V and 0V).
J