W i r i n g R e c e i v e r s
The receiver wires connect to power terminals or terminals on the I/O slots inside the con-
trol enclosure. The number of receivers and options in the conveying system will determine
the number of connections that are required. Refer to electrical prints provided with the
FLX for all electrical connections to the receiver control or Maintenance/Card Wire Number
screen. All receiver inputs and outputs are 24VDC unless the AC version was installed.
W i r i n g P u m p s
The pump wires connect to power terminals or terminals on the I/O slots inside the control
enclosure. The number of pumps in the conveying system will determine the number of
connections that are required. Refer to the electrical prints included with the FLX for all
connections or Maintenance/Card Wire Number screen. All pump inputs and outputs are
24VDC unless the AC version was installed.
W i r i n g P u r g e , Po c k e t , o r R a t i o Va l v e s
( o p t i o n a l )
The FLX can operate purge and/or pocket conveying valves, which are used in central dry-
ing and distribution systems. The pocket valve allows multiple loaders to draw dry material
as needed from a single drying hopper. Refer to electrical prints provided with the FLX for
all electrical connections to the loader control or Maintenance/Card Wire Number screen.
All valve outputs are 24VDC unless the AC version was installed.
Te s t i n g t h e F L X
Once the system is completely connected:
1
Check that all connections are terminated correctly.
2
Provide power to the FLX.
3
Wait for the control to initialize. The control
will check the I/O connections during the boot-
up and initialization process. This will take up
to 10 seconds.
I n s t a l l a t i o n l
3 - 1 3