TFTP Error Messages
The host with the bootfile may pass back a TFTP error message, which the PortServer will
display in the alphanumeric display. This message will be in the form En, where n can be one
of the following:
0
Error not defined, see error message (if any)
1
File not found
2
Access Violation
3
Disk Full or allocation exceeded
4
Illegal TFTP operation
5
Unknown transfer ID
6
File already exists
7
No such user
If the remote still will not work, push both arrow buttons (
and check that the boothost ip address is correct, and that the bootfile path and name are
correct. Also ensure that your system supports TFTP.
To return to automatically booting from ROM, enter:
set config boothost=255.255.255.255

flow

Syntax:
set flow
The set flow commands set or display the hardware and software flow control parameters for
RS-232 serial ports. set flow range is used to specify multiple ports, or one specific port.
Options are:
aixon
altpin
ixany
ixoff
Each of the above will have their own options, as outlined in the following descriptions. (More
than one option can be included in a command.)
Page 44 Ÿ Command Reference
option=value
cts
dcd
ixon
range
and
) to boot from the ROM,
dsr
dtr
ri
rts
itoss
save