Operating Mode Menu (Oper) - Newport Pt32 Operator's Manual

Temperature, process and strain controllers, platinum series
Table of Contents

Advertisement

PLATINUM Series Controllers User's Guide
Level
Level
Level
2
3
4

5.3 Operating Mode Menu (oPER)

The following table maps the Operating Mode (oPER) navigation:
Level
Level
Level
2
3
4
RUN
SP1
____
SP2
____
MANL
M.CNt
____
M.INP
____
PAUS
StoP
L.RSt
VALy
PEAk
Stby
tARE
Level
Level
5
6
oN
Soak events on for this segment
Normal Run Mode, process value displayed, SP1 in optional secondary display
Shortcut to change Setpoint 1, current Setpoint 1 value in main display
Shortcut to change Setpoint 2, current Setpoint 2 value in main display
Manual Mode, the RIGHT and LEFT buttons control output, displays M##.#
Manual Mode, the RIGHT and LEFT buttons simulate the input for testing
Pause and hold at current process value, display flashes
Stop controlling, turn off outputs, process value rotating flash, Alarms remain
Clears any latched Alarms;
Displays the lowest input reading since the VALy was last cleared
Displays the highest input reading since the PEAk was last cleared
Standby Mode, outputs, and Alarm conditions disabled, displays Stby
TARE option - only available if enabled in INPt
Complete Menu Structure
Notes
Notes
Alarms menu
also allows digital input reset