Alarm Off Delay (Prog > Alm.1, Alm.2 > De.of); Output Channel 1-6 Configuration (Prog > Out.1-Out.6) - Newport Pt32 Operator's Manual

Temperature, process and strain controllers, platinum series
Table of Contents

Advertisement

PLATINUM Series Controllers User's Guide
7.3.11 Alarm Off Delay (PRoG > ALM.1, ALM.2 > dE.oF)
Select the Alarm Off Delay (dE.oF) parameter.
Set the number of seconds to delay cancelling the Alarm. (The default is 0.) This setting can be
used to prevent Alarm chatter.
Confirm the value.
7.4 Output Channel 1–6 Configuration (PRoG > oUt.1–oUt.6)
Navigate to the desired output channel. The number and type of output channels on the
PLATINUM Series are automatically recognized by the device. The following output names
display, replacing the generic oUt.1 through oUt.6 references used in this document:
StR1 – Single Throw Mechanical Relay number 1
StR2 – Single Throw Mechanical Relay number 2
StR3 – Single Throw Mechanical Relay number 3
StR4 – Single Throw Mechanical Relay number 4
dtR1 – Double Throw Mechanical Relay number 1
dtR2 – Double Throw Mechanical Relay number 2
SSR1 – Solid State Relay number 1
SSR2 – Solid State Relay number 2
SSR3 – Solid State Relay number 3
SSR4 – Solid State Relay number 4
dC1
dC2
dC3
ANG1 – Analog output number 1
IdC1
IdC2
IAN1 – Isolated Analog output number 1
Note:
All output channels have the same menu structure. However, only those parameters
that apply for the type of output being configured appear in that output's menu.
Select the indicated output channel.
Navigate to the desired submenu. Submenus include the following:
ModE – Allows the output to be set up as a control, Alarm, retransmission, or
Ramp/Soak event output; the output can also be turned off
CyCL – PWM pulse width setting for DC pulse, mechanical relay, and solid state
relay outputs
RNGE – Sets the voltage or current range for analog outputs
Select the indicated setting.
– DC Pulse output number 1
– DC Pulse output number 2
– DC Pulse output number 3
– Isolated DC Pulse output number 1
– Isolated DC Pulse output number 2
Reference Section: Programming Mode (PRoG)
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt16Pt8dPt16dPt8ePt8pt

Table of Contents