S.10.025
Minimum
Default
Type
Display Format
Coding
This parameter specifies the IP address of the destination device for the Tx2 link. If Tx2
Link Transmission Type (S.10.024) is set to either broadcast or one of the multicast
settings this parameter will display the appropriate address.
This parameter value is not locked and may be changed by the user, if this value is
NOTE
changed to any of the multicast addresses (Multicast1, Multicast2, Multicast3 or
Multicast4) or the broadcast address then Tx2 Link Transmission Type (S.10.024) will
indicate the appropriate setting.
S.10.026
Minimum
Default
Type
Display Format
Coding
Defines, in milliseconds, the rate at which Tx2 Link will be transmitted. A value of zero
disables the transmission of data.
S.10.029
Minimum
Default
Type
Display Format
Coding
SI-Ethernet User Guide
Issue: 1
Tx2 Destination Address
0
Maximum
(Display:0.0.0.0)
0
Units
(Display:0.0.0.0)
32 Bit User Save Update Rate
IP Address
Decimal Places
RW, BU
Tx2 Message Rate
0
Maximum
0
Units
8 Bit User Save
Update Rate
None
Decimal Places
RW, BU
Tx2 Link Status
-30
Maximum
0
Units
8 Bit Volatile
Update Rate
None
Decimal Places
RO, TE
4294967295
(Display: 255.255.255.255)
Read on reset
0
100
ms
Read on reset
0
2
Write on reset
0
59