TILT MODELS
Electrical conductors must be flexible and capable of accommodating the washer movements
during the loading and unloading operations and secured at their ends.

3.6.2. HS-6040, HS-6057, EH090, EH130 models

The connection of the external dosing electrical signals takes
place on the terminals of A8 board, located in the electrical
connection box (box which contains the switch breaker) Fig.
3.14.
Remove protection cover A of the connection box.
Insert the conductor in Ed and secure it with the fixing
device.
Once the conductor connection is done, REPLACE
LOCK THE COVERS CORRECTLY.
POTENTIAL FREE RELAY CONTACTS
Connect the cables between the washer and the dosing unit
to A8 board in the order indicated in the table in section
3.6.4. (Figure 3.15).
Connect the common dosing cable to the terminal identified
as COM.
IMPORTANT
This connection allows for the maximum strength at
each of the 1A outputs.
The dosing signals ARE NOT PROTECTED by the
washer fuses.
RELAY CONTACTS POWERED FROM THE WASHER
CONTROL CIRCUIT.
Supply terminal identified as COM from terminal X1-1 of
A8 board (cable not supplied), Fig. 3.16.
Supply common phase of the signal outputs from terminal
X1-2 of A8 board.
Dosing outputs to the dosing unit: connect in the order
mentioned in the table in section 3.6.4.
IMPORTANT
This connection allows for the maximum strength at each of the 50mA outputs. Higher consumption
can prevent the washer from functioning correctly.
This connection can aggravate any problems produced by a fault in the grounding connection, both
of the washer itself and of the external dosing equipment.