Sk, Sd And Swift™ Wireless Slc Device Installation; List Of Sk Slc Devices - Honeywell 6820EVS Installation And Optimization Manual

Addressable fire system emergency voice system
Hide thumbs Also See for 6820EVS:
Table of Contents

Advertisement

Model 6820 / 6820-EVS Installation Manual
Section 7
SK, SD and SWIFT™ Wireless SLC Device Installation
To avoid the risk of electrical shock and damage to the unit, power should be OFF at the control panel while installing or
servicing.
7.1

List of SK SLC Devices

The following SK and wireless SLC devices can be used with the control panel. SK detectors include a 6" base.
See the appropriate section number in this manual or the device installation instructions (packaged with the
device) for more information.
Note: The control panel supports the use of either SK SLC devices or SD SLC devices. You cannot install both
SLC device types on the control panel.
SK
Part Number
SK-Photo
SK-Photo-T
SK-PhotoR
SK-Acclimate
SK-Beam
SK-Beam-T
SK-Duct
SK-Heat
SK-Heat-ROR
SK-Heat-HT
SK-Pull-SA
SK-Pull-DA
SK-ISO
SK-Monitor
SK-Minimon
SK-Monitor-2
SK-Mon-10
SK-Relay
SK-Relay-6
SK-Relaymon-2
SK-Zone
SK-Zone-6
SK-Control
SK-Control-6
SK-Fire-CO
Table 7-1: SK SLC Devices
Model Name/Description
Photoelectric smoke detector
Photoelectric smoke detector with thermal (135°F)
Photoelectric detector with remote test capability
Multi criteria photoelectric smoke detector with thermal (135°F)
Reflected beam smoke detector without test feature
Reflected beam smoke detector with test feature
Photoelectric duct smoke detector with extended air speed range
Fixed temperature thermal detector (135°F)
Rate-of-rise thermal detector with 135° fixed temperature
Fixed high temperature thermal detector (190°F)
Addressable single action pull station
Addressable dual action pull station
Fault isolator module
Monitor module
Mini monitor module
Dual input monitor module
10 input monitor module
Addressable relay module
Six relay control module
Dual relay/monitor module
Addressable zone interface module
Six zone interface module
Supervised control module
Six circuit supervised control module
CO Smoke Detector
Caution!
7-1
LS10144-001SK-E
Installation
Instruction PN
I56-3426-001
I56-3433-001
I56-3432-000
I56-3429-000
I56-3446-000
I56-3447-000
I56-3445-000
I56-3442-000
I56-3444-000
I56-3435-000
I56-3443-000
I56-3438-000
I56-3439-000
I56-3735-000
I56-3440-000
I56-3441-000
I56-3436-000
I56-3437-000
I56-3945-000

Advertisement