5-1. SPECIAL PROGRAM
MODE (Continued)
No. Cook
Product
Cycles
Fish
2
French Fries
8
Chicken
4
Aug. 2014
Filter Tracking Mode (SP-8)
Filter Tracking signals the operator when the oil needs filtering
by counting the number Cook Cycles between filters
Press ► button and "SP-8" and "FILTER TRACKING
MODE" show in the display. Use the ▲ and ▼ buttons to
choose either "1.MIXED" filter tracking or "2.GLOBAL".
GLOBAL means all the products have the same number
of cook cycles between filters.
MIXED means each product may be set with different number
Cycle
of cook cycles between filters. The controls adds the cycle
Count
counts (see example at left) and when the counts equal 1 or
1/2
greater, filtering is suggested. Ex: 1 load of fish, 2 loads of
1/8
1/4
french fries, a load of chicken equals 1. 1/2 + 1/8+1/8+1/4=1.
MIXED
If MIXED is selected, press ► button and "SP-8A" and "SUG-
GEST FILTER AT ..." shows in the left display, and a value
between 75% and 100% shows on the right display. Press the ▲
and ▼ buttons to change this value.
The lower the value, the sooner the control recommends to
filter. Ex: If set to 75%, the control suggest filtering after 3/4
of the programmed cook cycles is met, whereas at 100%, all
the cook cycles must be completed before the control suggest
filtering.
Press ► and "SP-8B" and "LOCKOUT ENABLED?" shows in
the left display. Press the ▲ and ▼ buttons to choose YES or
NO.
If set to YES, when the controls suggest filtering, "FILTER
LOCKOUT"/"YOU *MUST* FILTER NOW", shows in the
display, and it refuses further cook cycles until the vat is fil-
tered.
Press ► and "SP-8C" and "LOCKOUT AT..." shows in the
left display and a value between 100% and 250% shows on the
right display. Press the ▲ and ▼ buttons to change this value.
The lower the value, the sooner the "lockout" occurs.
Ex: If set at 100%, "lockout" occurs when the cycle counts
reaches 1 or greater. Set at 200%, twice as many cycles are
counted before "lockout" occurs. See example above.