6-7. TEMPERATURE PROBE
REPLACEMENT
(Continued)
Aug. 2014
Replacement:
1. Pull-out on the drain valve knob and drain the oil from the
vat.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Using a 3/8" socket, remove the 2 screws securing the
burner jet bracket and remove bracket.
3. Pull both burner jets from unit.
4. Using a 1/2" wrench, remove the nut on the compression
fitting, and remove the temperature probe from the vat.
5. Using a terminal extractor, remove the probe terminals from
the connector and pull remove probe from unit
43
Model EEG-241, 242, 243, 244