Troubleshooting - Henny Penny EEG-242 Technical Manual

Evolution elite gas open fryer
Hide thumbs Also See for EEG-242:
Table of Contents

Advertisement

7-1. TROUBLE SHOOTING
(Continued)
Problem
POWER switch ON
but fryer completely
inoperative
"E-10"
Vat is under-filled
Aug. 2014
Cause
Open circuit
Hight limit
JIB is low or empty
JIB oil line is clogged or
collapsed
Filter pan needs cleaned
5
Model EEG-241, 242, 243, 244
Correction
Plug fryer in
Check breaker or fuse at supply box
Let unit cool down (15-20 minutes),
push up on metal reset button under
right side of the controls; if high limit
does not reset, high limit must be
replaced
Fill the JIB
Check JIB line
Clean filter pan and change paper or
pad

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eeg-241Eeg-244Eeg-243