5-4. TECH MODE (Continued)
Aug. 2014
T-20 - AIF Board Inputs:
E = Stop button
P = Drain Pan
JL = JIB
R = RTI
DT = Discard Tank
T-21 - PUMPS & VALVES
Press ▼ button and "LIGHTS" "DLT_" shows in displays.
Press
and left Filter Beacon lights (split vats) and press
button and right Filter Beacon lights (display shows "DLTo"
when on)
Press ▼ button and "VALVES" "DcRc" shows in displays.
Press
to open and close the return valve.
"DcRc" means valve is closed, "DcRo" means valve is open.
(Driven by the control board)
Press ▼ button and "DISCARDc" and "JIBFILLc" shows in
the displays. (Driven by the AIF board)
Press
to open and close the RTI discard valve (display
shows "DISCARDo" when open)
Press
to open and close the RTI JIB fill valve (display
shows "JIBFILLo" when open)
Press ▼ button and "PUMP FP_" and "JP_ NP_" shows in the
displays. (Driven by the AIF board)
Press
to turn off and on the filter pump (display shows
"FP*" when on)
Press
to turn off and on the JIB pump (display shows
"JP*" when on)
Press
to turn off and on the new oil pump (if available -
display shows "NP*" when on)
33
Model EEG-241, 242, 243, 244
Ex = E-Stop pressed.
Px = drain pan is missing.
Jx = JIB oil level is low.
Rx = RTI System NOT Detected
DTx = tank full