5-4. TECH MODE (Continued)
Aug. 2014
Press ▼ button and "OUT F_J_" and "N_DI_oJF_" shows in
the displays.
AIF Board Outputs:
Current outputs status from AIF board.
F = Filter Pump.
(Fx = Filter pump is on)
J = JIB Pump.
(Jx = JIB pump is on)
N = New Oil Pump. (Nx = RTI new oil pump on)
(if present)
DI = Discard Valve. (DIo = Disc. valve open/DIc=closed)
(if present)
JF = JIB Fill Valve.
(JFo = JIB fill valve open/JFc=closed)
Press ▼ button and "REQ F_J_" and "N_DI_JF_" shows in
the displays.
AIF Board Outputs Requested by the Control Board:
Current outputs status from AIF board.
F = Filter Pump.
(Fx = Filter pump is on)
J = JIB Pump.
(Jx = JIB pump is on)
N = New Oil Pump. (Nx = New oil pump on)
(if present)
DI = Discard Valve. (DIo = Disc. valve open/DIc=closed)
(if present)
JF = JIB Fill Valve.
(JFo = RTI JIB fill valve open/JFc=-
closed)
35
Model EEG-241, 242, 243, 244