1-4. ERROR CODES (Continued)
"E-60"
"FILTER IN USE"
"E-70C"
"E-83-A"
"E-83-B"
"E-83-C"
"E-83-D"
"E-83-E"
"E-83-J"
"E-83-R"
"E-93-1"
"24 VDC SUPPLY
TRIPPED"
Aug. 2014
AIF PC board not
communitcating with
control PC board
Drain valve jumper
wire missing or
disconnected
Pressure too high
Pressure too high
Pressure too high
Pressure too high
Pressure too high
Bulk JIB FILL
switch ON when
pressure too high
Bulk Dispose switch
ON when pressure
too high
Autolift motor
malfunction or
failure
Press power button to turn vat off, wait 15 seconds,
and turn back on again. If "E-60" persists, have
connector between the PC boards checked; replace
AIF PC board or control PC board, if necessary
Have the jumper wire checked on the PC board at
drain switch interlock position
Check filter system in Vat #1
Check filter system in Vat #2
Check filter system in Vat #3
Check filter system in Vat #4
Check filter system in Vat #5
Check JIB fill valves
Check Bulk Dispose quick-disconnect behind
fryer
If AutoLift feature is not operating, have each of the
AutoLift motors checked.