1-4. ERROR CODES (Continued)
"E-20-A"
"FAN SENSOR
STUCK
CLOSED"
"E-20-B"
"NO DRAFT"
"CHECK FAN"
"E-20-D"
"IGNITION"
"FAILURE"
"E-21"
"E-22"
"NO HEAT"
"CHECK GAS
VALVE"
"E-41 " / "E-46"
"E-47"
"E-48"
"E-54-C"
Aug. 2014
Pressure Switch
failure
Wiring problem
I/O board failure
Pressure switch
failure/ hose loose
Draft fan failure/ low
voltage
Flue or hood
obstruction
Failure to ignite/ no
flame sense
Plugged atmospheric
equalization hole
in regulator cap
resulting in pilot
flame slowly fading
Slow heat recovery
Burner not igniting
Programming failure •
Analog converter
chip or 12 volt
supply failure
Input system error
Temperature input
error
If fan is not running, have pressure switch
checked; should be open circuit if no air
pressure
If fan is running, wiring error, or relay on I/O board
closed
Press power button to vat off and back on again,
if E-20-B persists, have pressure switch checked;
should be open circuit if no air pressure; make sure
hose is connected to fan and pressure switch
Have draft fan checked; low voltage going to fan
Check the fryer flue and hood system for obstructions
Press power button to vat off and back on again, if
E-20-D persists, check gas line connections; check
gas shutoff valve; check ignition module; check gas
valve; check flame sensor gap; check gas valve, and
check ignition module wiring
Clear obstruction from hole
Have a certified service technician check the fryer for
correct voltage to the unit; have heat circuit checked;
have unit checked for loose or burnt wire
Have gas valve and heat circuit checked
Press power button to vat off and back on again,
if any of the error codes, have the controls re-
initialized; if error code persists, have the control
board replaced
Press power button to vat off and back on again,
if "E-47" persists, have the I/O board, or the
PC board replaced; if speaker tones are quiet,
probably I/O board failure; have the I/O board
replaced
Have PC board replaced
Turn switch to OFF, then back to ON; have
control PC board replaced if "E-54C" persists