Using Binary Editor - Seiko RP-E10 Operation Manual

Table of Contents

Advertisement

Item
Send Command
Command data
Edit...
*1:
You can specify only one of [Print Start] or [Print End].
*2:
The initial value of [Print End].
*3:
The initial value of [Print Start].
*4:
Enter an even number. If you enter an odd number, it is internally rounded to a value
within the range.
*5:
It should be equal to or greater than four times of the ON time to protect circuits.
*6:
You cannot enter data directly.
Reference
Logo
Function to print a predefined image as logo. An NV image is used as the logo image.
For details of the NV image, see "5.6 NV Image".

3.4.8 Using Binary Editor

For a control in which you need to enter arbitrary numeric data, the binary editor is used.
Click the [Edit...] button for such a setting to display the window below.
Directly enter numeric values as hexadecimal numbers and click the [OK] button to confirm
the value.
Description ("
Sets the command to send.
Displays the command to send.
To enter data, use the binary editor which is displayed by clicking the
[Edit...] button.
Starts the binary editor.
Data entered in the binary editor is displayed in [Command data].
Up to 128 bytes can be specified.
For details of the binary editor, see "3.4.8 Using Binary Editor".
Screen 3-7 Binary editor
3-16
": Initial Value)
*6