Table 5. Dimensions of the PowerEdge C6400 enclosure
Xa
Xb
482.6 mm (19 inches) 448 mm (17.63
inches)
Chassis weight
Table 6. Chassis weight of the PowerEdge C6400 enclosure with PowerEdge C6420 sleds
System
12 x 3.5-inch hard drive systems
24 x 2.5-inch hard drive systems
No backplane systems
PSU specifications
The PowerEdge C6400 enclosure supports two AC power supply units (PSUs).
Table 7. PSU specifications
PSU wattage
Class
2400 W AC
Platinum
2000 W AC
Platinum
1600 W AC
Platinum
NOTE:
Heat dissipation is calculated using the PSU wattage rating.
NOTE:
This system is also designed to connect to the IT power systems with a phase to phase voltage not exceeding 240 V.
NOTE:
If a system with 2400 W AC PSU operates at low line 100–120 V AC, then the power rating per PSU is derated to 1400 W.
NOTE:
If a system with 2000 W AC PSU operates at low line 100–120 V AC, then the power rating per PSU is derated to 1000 W.
NOTE:
If system with 1600 W AC PSU operates at low line 100–120 V AC, then the power rating per PSU is derated to 800 W.
Hard drives and storage specifications
The PowerEdge C6420 sled supports SAS and SATA hard drives and Solid State Drives (SSDs).
Y
86.8 mm (3.41
inches)
Maximum weight (with all sleds and drives)
43.62 Kg (96.16 lb)
41.46 Kg (91.40 lb)
34.56 Kg (76.19 lb)
Heat dissipation
(maximum)
715 BTU/hr
635 BTU/hr
475 BTU/hr
Za
Zb
26.8 mm (1.05
763.2 mm (30.28
inches)
inches)
Frequency
Voltage
100–240 V AC,
50/60 Hz
autoranging
100–240 V AC,
50/60 Hz
autoranging
100–240 V AC,
50/60 Hz
autoranging
Zc
797.3 mm (31.38
inches)
Maximum input current
14 A–16 A
11.5 A
10 A
Technical specifications