HEATER ENGINE - GENERAL INSTALLATION

ELECTRICAL SUPPLY

If a power point is used it MUST BE 230 V, rated at 10A and MUST BE earthed.
This power point MUST NOT be located above the heater. Alternatively the
appliance can be direct wired if the power supply is to be concealed.
The heater engine is fitted with a 1.5 m power cord and three pin plug
exits the appliance from the rear panel at the lower left.
Direct Wired Installations
Alternatively the appliance can be direct wired if the power supply is to be
concealed.
A qualified electrician will need to be consulted where a direct
wired installation is required. Any such installation must comply
IMPORTANT
with the requirements of AS/NZS 5601, AS/NZS 3000 and any
other relevant local regulations.
Using Existing Externally Mounted Power Points on Inbuilt Installations
If you already have an existing wall plug located outside of the intended fireplace or enclosure you may redirect the
power cord and plug assembly through the front panel. With Fascia assembly removed, simply redirect the cord
and plug assembly with grommet from the rear of the unit, underneath the fire-box to the front of the unit, (either
left or right).
Carefully remove the pre-punched sheet metal 'knock-out' section located in the lower left or right edge
Fascia Assembly. Refit the cord and plug assembly to the Fascia assembly ensuring the grommet is fitted to the
sheet metal. Excess cord may be left in the cavity below the fire box. DO NOT coil excess cord.