How to Order

5.3 Type Code

Table 5.1 Type Code
Description
Product group
Series and product type
5
5
Power size
Mains voltage
Enclosure
RFI filter
Brake
Display
Coating PCB
Mains option
Adaptation A
Adaptation B
Software release
Table 5.2 Type Code Description
40
®
VLT
Micro Drive FC 51 Design Guide
Pos
Possible choice
1-3
Adjustable Frequency Converters
4-6
Micro Drive
7-10
0.18-22 kW
11-12
S2: Single phase 200-240 V AC
T 2: Three phase 200-240 V AC
T 4: Three phase 380-480 V AC
13-15
IP20/Chassis
16-17
H3: RFI filter A1/B (reduced cable length*)
18
B: Brake chopper included (from 1.5 kW and up)
X: No brake chopper included
19
X: No Local Control Panel
N: Numerical Local Control Panel (LCP)
P: Numerical Local Control Panel (LCP) with potentiometer
20
C: Coated PCB
X: No coated PCB
21
X: No mains option
22
X: No adaptation
23
X: No adaptation
24-27
SXXX: Latest release - std. software
MG02K302 - Rev. 2013-12-03