2.7.5 Example with Varying Flow over 1
Year
2
2
This example is calculated based on pump characteristics
obtained from a pump datasheet.
The result obtained shows energy savings in excess of 50%
at the given flow distribution over a year. The pay back
period depends on the price per kWh and price of
frequency converter. In this example it is less than a year
when compared with valves and constant speed.
Energy savings
P
=P
shaft
shaft output
Illustration 2.6 Flow Distribution over 1 Year
14
®
VLT
Micro Drive FC 51 Design Guide
(mwg)
60
50
40
30
20
10
0
(kW)
60
50
40
30
20
10
0
Illustration 2.7 Energy
m
3
/
h
%
350
5
300
15
250
20
200
20
150
20
100
20
Σ
100 8760
Table 2.5 Result
MG02K302 - Rev. 2013-12-03
H
s
B
C
1050rpm
750rpm
100
200
P
shaft
B
1
1050rpm
C
1
750rpm
100
200
Distri-
Valve regulation
bution
Hours
Power
Consump-
tion
A
- B
kWh
1
1
438
42.5
18.615
1314
38.5
50.589
1752
35.0
61.320
1752
31.5
55.188
1752
28.0
49.056
1752
23.0
40.296
275.064
A
1650rpm
1350rpm
(
3
)
m
/h
300
400
A
1
1650rpm
1350rpm
(
)
300
400
m
3
/h
Frequency converter
control
Power
Consump-
tion
A
- C
kWh
1
1
42.5
18.615
29.0
38.106
18.5
32.412
11.5
20.148
6.5
11.388
3.5
6.132
26.801