Faults with the diffuse sensor or in the production process can result in signal wobbles. The
measured value then changes the switching threshold by 100 % (object detected - object not
detected). You can prevent this switching threshold wobble using the switching hysteresis
parameter. This will ensure a stable output signal on the sensor.
You can assigned parameters to 5 %/10 %/20 %/50 % for switching hysteresis.
Prerequisites
You can only set the switching hysteresis parameter for diffuse sensors with background
fadeout.
Operating principle
Figure 5-2