Emerson Rosemount 8800D Series Reference Manual page 25

Vortex flowmeter
Hide thumbs Also See for Rosemount 8800D Series:
Table of Contents

Advertisement

Reference Manual
00809-0100-4004, Rev DC
Table 2-2. Fast Keys for Rosemount 8800D HART 7 Device Revision 2 (DD Revision 1)/ HART 5 Device
Revision 3 (DD Revision 1)
Function
Analog Output
Analog Trim
Base Mass Unit (MF)
Base Process Density
Base Time Unit (CVF)
Base Time Unit (MF)
Base Time Unit (VF)
Base Volume Unit (CVF)
Base Volume Unit (VF)
Compensated K-Factor
Conversion Factor (CVF)
Conversion Factor (MF)
Conversion Factor (VF)
Date
Corrected Volumetric Flow
Corrected Volumetric Flow Units 2,2,2,6,2
Density Ratio
Descriptor
Device ID
Device Status
Display
Electronics Temp
Electronics Temp Units
Final Assembly Number
Fixed Process Density
Fixed Process Temperature
Flange Type
Flow Simulation
Fourth Variable
Loop Test
Lower Range Value
Lower Sensor Limit
Mass Flow
Mass Flow Units
Message
Meter Factor
Minimum Span
Optimize DSP
Percent of Range
Pipe Inside Diameter
1.
These items are in a list format without numeric labels. To access these features, you must scroll to this option in the HART Communicator.
Configuration
Fast Key
3, 4, 3, 1
Polling Address
3, 4, 3, 7
Primary Variable
2, 2, 2, 8, 1
Process Fluid Type
2, 2, 3, 2, 1
Process Variables
2, 2, 2, 9, 4
Pulse Output
2, 2, 2, 8, 4
Pulse Output Test
2, 2, 2, 7, 4
Reference K-Factor
2, 2, 2, 9, 1
Reset Transmitter
2, 2, 2, 7, 1
Restore Default Filters
2, 2, 1, 2, 2
Restore Factory Calibration
2, 2, 2, 9, 2
Revision Numbers
2, 2, 2, 8, 2
Scaled Analog Trim
2, 2, 2, 7, 2
Second Variable
(1)
2, 2, –
, 1, 5
Self Test
3,2,1
Set Damping
Set Low Flow Cutoff
2, 2, 3, 4
Set Low-pass Corner Frequency
(1)
2, 2, –
, 1, 6
Set Trigger Level
(1)
2, 2, –
, 1
Shedding Frequency
1, 1
Signal Strength
2, 1, 1, 2
Special Flow Unit (CVF)
3, 2, 6
Special Flow Unit (MF)
2, 2, 2, 6, 7
Special Flow Unit (VF)
2, 2, 1, 4, 3
Special Volume Unit
2, 2, 1, 1, 5
Tag
2, 2, 1, 1, 4
Third Variable
2, 2, 1, 4, 2
Total
3, 5, 1, 2, 1
Totalizer Configuration
2, 2, 2, 4
Totalizer Control
3, 5, 2, 7
Transmitter Mode
2, 2, 4, 1, 4
Upper Range Value
2, 2, 4, 1, 6
Upper Sensor Limit
3, 2, 1
Variable Mapping
2, 2, 2, 6, 5
Velocity Flow
(1)
2, 2, –
, 1, 7
Velocity Flow Units
2, 2, 1, 1, 7
Velocity Measurement Base
2, 2, 4, 1, 7
Volume Flow
2, 1, 1, 3
Volume Flow Units
3, 4, 3, 2
Wetted Material
2, 2, 1, 1, 6
Write Protect
Function
Configuration
May 2016
Fast Key
(1)
2, 2, –
, 2, 1
2, 2, 2, 1
2, 2, 1, 1, 3
3, 2, 3
3, 2, 5, 3
3, 5, 3, 4
2, 2, 1, 2, 1
3, 4, 4, 1, 2
2, 1, 4, 6
3, 4, 3, 9
(1)
2, 2, –
, 2
3, 4, 3, 8
2, 2, 2, 2
3, 4, 4, 1, 1
2, 1, 4, 1
2, 1, 4, 3
2, 1, 4, 4
2, 1, 4, 5
3, 2, 5, 1
3, 4, 2, 1, 4
2, 2, 2, 9, 5
2, 2, 2, 8, 5
2, 2, 2, 7, 5
2, 2, 2, 7, 3
(1)
2, 2, –
, 1, 1
2, 2, 2, 3
2, 2, 4, 3, 1
2, 2, 4, 3, 3
2, 2, 4, 3, 2
2, 2, 1, 1, 1
2, 2, 4, 1, 3
2, 2, 4, 1, 5
2, 2, 2, 5
3, 2, 1
2, 2, 2, 6, 3
2, 2, 2, 6, 4
3, 2, 1
2, 2, 2, 6, 1
2, 2, 1, 4, 1
(1)
2, 2, –
, 4, 1
17

Advertisement

Table of Contents
loading

Table of Contents