Table A-13. Saturated Steam Flow Rate Limits (Assumes Steam Quality is 100%)
Flow
Process
rate
pressure
limits
15 psig
max
(1,03 bar G)
min
25 psig
max
(1,72 bar G)
min
50 psig
max
(3,45 bar G)
min
100 psig
max
(6,89 bar G)
min
150 psig
max
(10,3 bar G)
min
200 psig
max
(13,8 bar G)
min
300 psig
max
(20,7 bar G)
min
400 psig
max
(27,6 bar G)
min
500 psig
max
(34,5 bar G)
min
Specifications and Reference Data
Minimum and maximum saturated steam flow rates
for line sizes 1
1½ Inch/DN 40
Rosemount
Rosemount
8800D
lb/hr
kg/hr
lb/hr
917
416
342
82.0
37.2
34.8
1204
546
449
93.9
42.6
39.9
1904
864
711
118
53.4
50.1
3270
1483
1221
155
70.1
65.7
4616
2094
1724
184
83.2
78.1
5956
2702
2225
209
94.5
88.7
8644
3921
3229
252
114
107
11362
5154
4244
295
134
125
14126
6407
5277
367
167
156
/
inch/DN 40 through 2 inch/DN 50
1
2
8800DR
Rosemount 8800D Rosemount 8800DR
kg/hr
lb/hr
155
1511
15.8
135
203
1983
18.1
155
322
3138
22.7
195
554
5389
29.8
255
782
7609
35.4
303
1009
9818
40.2
344
1464
14248
48.5
415
1925
18727
56.7
487
2393
23284
70.7
605
Reference Manual
00809-0100-4004, Rev DC
2 Inch/DN 50
kg/hr
lb/hr
kg/hr
685
917
61.2
82.0
37.2
899
1204
70.2
93.9
42.6
1423
1904
88.3
118
53.4
2444
3270
1483
116
155
70.1
3451
4616
2094
137
184
83.2
4453
5956
2702
156
209
94.5
6463
8644
3921
189
252
8494
11362
5154
221
295
10561
14126
6407
274
367
416
546
864
114
134
167
113