Reference Manual
00809-0100-4004, Rev DC
Process connections
Mounts between the following flange configurations:
ASME B16.5 (ANSI): Class 150, 300, 600, 900, 1500
EN 1092-1: PN 10, 16, 25, 40, 63, 100, 160
JIS: 10K, 20K, and 40K
Weld-end: Schedule 10, Schedule 40, Schedule 80, Schedule 160
Mounting
Integral (standard)
Electronics are mounted on meter body.
Remote (optional)
Electronics may be mounted remote from the meter body. Interconnecting coaxial cable
available in nonadjustable 10, 20, 30, 33, and 50 ft (3.0, 6.1, 9.1, 10, and 15.2 m) lengths.
Consult factory for non-standard lengths up to 75 ft (22,9 m). Remote mounting hardware
includes a pipe mount bracket with one u-bolt.
Armored remote cables are also available in lengths of 10, 20, 33, 50 and 75 feet. The
armored remote option comes standard with an aluminum gland to connect the cable to
the meter and electronics. A stainless steel gland is provided when ordered in conjunction
with a stainless steel electronics housing.
Temperature limitations for integral mounting
The maximum process temperature for integral mount electronics is dependent on the
ambient temperature where the meter is installed. The electronics must not exceed 185 °F
(85 °C). Refer to
122
Figure
A-1.
Specifications and Reference Data
Specifications and Reference Data
May 2016