Table A-14. Saturated Steam Flow Rate Limits (Assumes Steam Quality is 100%)
Flow
Process
rate
pressure
limits
15 psig
max
(1,03 bar G)
min
25 psig
max
(1,72 bar G)
min
50 psig
max
(3,45 bar G)
min
100 psig
max
(6,89 bar G)
min
150 psig
max
(10,3 bar G)
min
200 psig
max
(13,8 bar G)
min
300 psig
max
(20,7 bar G)
min
400 psig
max
(27,6 bar G)
min
500 psig
max
(34,5 bar G)
min
114
Minimum and maximum saturated steam flow rates
for line sizes 3 inch/DN 80 through 4 inch/DN 100
3 Inch/DN 80
Rosemount
Rosemount
8800D
lb/hr
kg/hr
lb/hr
3330
1510
1511
298
135
135
4370
1982
1983
341
155
155
6914
3136
3138
429
195
195
11874
5386
5389
562
255
255
16763
7603
7609
668
303
303
21630
9811
9818
759
344
344
31389
14237
14248
914
415
415
41258
18714
18727
1073
487
487
51297
23267
23284
1334
605
605
Specifications and Reference Data
8800DR
Rosemount 8800D Rosemount 8800DR
kg/hr
lb/hr
685
5734
61.2
513
899
7526
70.2
587
1423
11905
88.3
739
2444
20448
116
968
3451
28866
137
1150
4453
37247
156
1307
6463
54052
189
1574
8494
71047
221
1847
10561
88334
274
2297
May 2016
4 Inch/DN 100
kg/hr
lb/hr
kg/hr
2601
3330
1510
233
298
135
3414
4370
1982
267
341
155
5400
6914
3136
335
429
195
9275
11874
5386
439
562
255
13093
16763
7603
522
668
303
16895
21630
9811
593
759
344
24517
31389
14237
714
914
415
32226
41258
18714
838
1073
487
40068
51297
23267
1042
1334
605