Specifications and Reference Data
May 2016
Table A-15. Saturated Steam Flow Rate Limits (Assumes Steam Quality is 100%)
Flow
Process
rate
pressure
limits
15 psig
max
(1,03 bar G)
min
25 psig
max
(1,72 bar G)
min
50 psig
max
(3,45 bar G)
min
100 psig
max
(6,89 bar G)
min
150 psig
max
(10,3 bar G)
min
200 psig
max
(13,8 bar G)
min
300 psig
max
(20,7 bar G)
min
400 psig
max
(27,6 bar G)
min
500 psig
max
(34,5 bar G)
min
Specifications and Reference Data
Minimum and maximum saturated steam flow rates
for line sizes 6 inch/DN 150 through 8 inch/DN 200
6 Inch/DN 150
Rosemount
Rosemount
8800D
lb/hr
kg/hr
lb/hr
13013
5903
5734
1163
528
513
17080
7747
7526
1333
605
587
27019
12255
11905
1676
760
739
46405
21049
20448
2197
996
968
65611
29761
28866
2610
1184
1150
84530
38342
37247
2965
1345
1307
122666
55640
54052
3572
1620
1574
161236
73135
71047
4192
1901
1847
200468
90931
88334
5212
2364
2297
8800DR
Rosemount 8800D Rosemount 8800DR
kg/hr
lb/hr
2601
22534
233
2015
3414
29575
267
2308
5400
46787
335
2903
9275
80356
439
3804
13093
113440
522
4520
16895
146375
593
5134
24517
212411
714
6185
32226
279200
838
7259
40068
347134
1042
9025
Reference Manual
00809-0100-4004, Rev DC
8 Inch/DN 200
kg/hr
lb/hr
kg/hr
10221
13013
914
1163
13415
17080
1047
1333
21222
27019
12255
1317
1676
36449
46405
21049
1725
2197
51455
65611
29761
2050
2610
66395
84530
38342
2329
2965
96348
122666
55640
2805
3572
126643
161236
73135
3293
4192
157457
200468
90931
4094
5212
5903
528
7747
605
760
996
1184
1345
1620
1901
2364
115