6.4.2
HardwareRequirements
The following hardware is required to implement the examples:
one digital input module 6ES5420-.... coded as IB4 *)
Addressing switch
Value
one digital output module 6ES5441 . . . . . coded as QB4
Addressing switch
Value
*) The following applies for the S5-1 15U:
one digital input module 6ES5420-.... (fixed slot addressing) inserted in slot number 1 in the cen-
tral controller (IB4 to IB7).
one digital output module 6ES5441 -..,, (fixed slot addressing) inserted in slot number 2 in the
central controller (QB8toQB11).
one IP247 positioning module coded as page number O (=> Section 3.3.2 "Setting the Module
Address") inserted in a CP slot in the central controller of the programmable controller.
Value
The remaining jumpers on the IP247 must be set for the specific equipment (=> Section 3.3.2
"Setting the Module Address").
128
128
128
pressed
off
on
4
pressed
off
on
4
4
Examples
6 - 5 5