Getting Started; Consignment; Setting The Configuration Register; Working Copy Of The Com247 Diskette - Siemens SIMATIC S5 Manual

Positioning module 1p 247 for stepper motors
Hide thumbs Also See for SIMATIC S5:
Table of Contents

Advertisement

Getting Stafled
5.3

Getting Started

5.3.1

Consignment

Under the order number 6ES5895-5SB22—, the manual includes, among other things, this
User's Guide, a 5 1/4 inch diskette anda31/2 inch diskette each with the file:
S5PEC1OX.CMD
The software package COM247 runs under the operating system S5- DOS, which is not part of
the consignment.
5.3.2

Setting the Configuration Register

If the operating system S5-DOS has never run on your PG, you must set the configuration regis-
ter of the PG using the test diskette. You must enter the memory capacity, the drive configura-
tion and other important PG characteristics in the configuration register to be able to inform
various programs (e.g. S5-DOS) of the hardware configuration. To set the configuration register,
you must insefi the test diskette supplied with the PG in drive A: and start the PG either by turn-
ing on the power or by using the key switch. Answer the prompt "CHANGE CONFIGURATION?"
with "Y" and then mak the appropriate information with "+" and the incorrect information with
"-". Once you have answered all the questions, you can remove the test diskette and continue
with PC P/M after a cold restart. The content of the configuration register is retained even when
power is switched off.
5.3.3

Working Copy of the COM247 Diskette

Before you use the COM247 diskette, you shouid make a working copy and put the original
away for safekeeping. To make a copy, use the PCP/M utility "DSKMAINT", with which you can
check, format and copy diskettes. (In more re~nt S5 versions, 'DSKMAiNT' has been replaced
by 'DISK'.)
5.3.3.1
Programmers with one Fioppy Disk Drive (PG685)
Start the PG by turning on the power or using the keyswitch
A > DSKMAiNT <R>
New diskette in drive A:
Formatted diskette in drive A:
insert the diskettes required by DSKMAINT in drive A:, the COM247 diskette is the
source diskette and the newiy formatted diskette is the target diskette.