Cleaning work should be undertaken regularly and carefully by qualifi ed and trained staff .
The staff must be familiar with the DIN EN 50177 provisions. They should be informed of
specifi c hazards during their training.
The following hazards may arise during cleaning work:
Health hazard from cleaning agents
Health hazard from inhaling powder lacquer
Use of unsuitable cleaning tools and aids
8.1.2

SAFETY INSTRUCTIONS

Explosive powder/air mixes!
Danger to life and damage to the device.
ORDER NUMBER DOC2345334
DANGER
Before starting cleaning or other manual work, the high-voltage
must be shut down and locked to prevent it from being switched
back on!
Use only electrically conductive tanks for cleaning liquids!
Ground the tank!
Preference should be given to non-fl ammable cleaning fl uids.
Flammable cleaning liquids may only be used if, after switching
off the high-voltage, all high-voltage conducting parts are
discharged to a discharge energy of less than 0.24 mJ before
they can be accessed.
Most fl ammable solvents have an ignition energy of around
0.24 mJ or 60 nC.
The cleaning agent's fl ash point must be at least 15 K above the
ambient temperature.
Only mobile industrial vacuum cleaners of design 1 (see
EN 60335-2) may be used to remove dust deposits.