Reproducible Setting Of The Nozzle Position - WAGNER PEA-C4XL-S Translation Of The Original Operating Manual

Automatic powder spray gun
Table of Contents

Advertisement

VERSION 03/2014
OPERATING MANUAL
7.8

REPRODUCIBLE SETTING OF THE NOZZLE POSITION

30°
15°
X
ORDER NUMBER DOC2345334
For a horizontal powder cloud, the
fl at spray nozzle is set where the
protective wedge is in the 0° position.
When attaching a round spray nozzle,
we recommend turning the protective
wedge to the 90° position to achieve
X
smoother coating (the protective
wedge is now in the vertical position).
It is possible to change this position as
needed for special applications.
On the nozzle body and electrode holders
there are X markings. The position can be
changed as required in 15° increments and
P_01095
later reproduced.
The union nut has to be removed for exact
positioning.
An adjustment tool is provided for the fl at
spray nozzle.
It permits turning the fl at spray nozzle
without damaging the electrodes and
without removing the union nut.
The union nut only has to be slackened.
P_01096
PEA-C4XL-S