Step 9: Terminate the Unused End of the Engage Cable

WARNING: Risk of Electrical Shock. Do not install the terminator cap while power is
connected.
NOTE: Adhere to the following requirements:
Use the terminator only once. If you open the terminator following installation, the
latching mechanism is destroyed. Do not reuse the terminator.
If the latching mechanism is defective, do not use the terminator.
Do not circumvent or manipulate the latching mechanism.
Use the terminator and no other method to seal the conductor end of the trunk.
Do not expose the terminator cap to directed, pressurized liquid (water jets, etc.).
Do not expose the terminator to continuous immersion.
Do not expose the terminator to continuous tension (e.g., tension due to pulling or
bending the cable near the terminator)
Do not install or use in potentially explosive environments.
Do not allow the terminator to come into contact with open flame.
Use the terminator cap assembly only when all parts are present and intact.
Fit the terminator cap using only the prescribed tools and in the prescribed manner.
Make sure that all seals are seated correctly in the wire organizer.
When stripping off the cable sheath, make sure that the conductors are not
damaged. If the conductors are damaged, proper system function cannot be assured.
a. Strip at least 60 mm (2.5 inches) of the
shielding from the conductors.
b. Slide the hex nut onto the Engage Cable.
c. Insert the Engage Cable all the way into
the wire organizer (up to the stop).
d. Bend the individual wires back into the
recesses in the wire organizer so that
they angle back toward the cable.
e. Cut the individual wires so that no excess extends outside of
the wire organizer. The portions that angle back will need to
extend enough to fit neatly into the 0.5 cm (0.2 in) recesses in
the wire organizer and flush with the edge of the cap.
f.
Place cap over the wire organizer.
g. Hold the cap stationary with an Enphase disconnect
tool, or insert a #2 Phillips screwdriver.
h. Use a 22 mm (7/8 inch) wrench to tighten the hex nut
until the latching mechanism is screwed all the way
to the base. Never unscrew the hex nut. This
action can twist and damage the cable.
i.
Use a tie wrap or cable clip to attach the cable to the
PV racking, so that the Engage Cable and terminator
do not touch the roof.
j.
Ensure that all cabling is located underneath the PV
module.
22
 2014 Enphase Energy Inc. All rights reserved.
M215 Installation and Operation
wire organizer
hex nut
cap
141-00012 Rev 06