Step 7: Terminate The Unused End Of The Cable; Step 8: Complete The Installation Of The Junction Box - enphase IQ7+ Installation And Operation Manual

Microinverters
Table of Contents

Advertisement

Step 7: Terminate the unused end of the cable

Terminate the unused end of the IQ Cable as follows:
Si. No
Description
1.
Remove 13 mm of the cable sheath from the
conductors. Use the terminator body loop to
measure.
2.
Slide the hex nut onto the cable.
3.
Insert the cable into the terminator body so that
the two wires land on opposite sides of the internal
separator. The grommet inside the terminator body
must remain in place.
4.
Insert a screwdriver into the slot on the top of the
terminator to hold it in place. Hold the terminator
body stationary with the screwdriver and turn only
the hex nut to prevent the conductors from
twisting out of the separator.
Torque the nut to 7.0 N m.
5.
Attach the terminated cable end to the PV racking
with a cable clip or tie wrap so that the cable and
terminator do not touch the roof.
NOTE: For India, the color of the live wire is red, and the neutral is black.
NOTE: Turn only the hex nut to prevent conductors from twisting out of the separator.
WARNING: The terminator cannot be re-used. If you unscrew the nut, you must discard the
terminator.

Step 8: Complete the installation of the junction box

A. Connect the IQ Cable to the junction box.
B. For more information, refer to the
code:
17
IQ7+ and IQ7A Installation and Operation Manual - India
Single-phase IQ Cable
wiring diagrams
© 2023 Enphase Energy Inc. All rights reserved.
Diagram
in this
manual.
IQ Cable uses the following color
August 2023
USM-00002-1.0