enphase M215-60-2LL-S23-IG Installation And Operation Manual page 36

M215 series. microinverter
Hide thumbs Also See for M215-60-2LL-S23-IG:
Table of Contents

Advertisement

M215-60-2LL-S22-IG, S23-IG, or S24-IG
Topic
Rated (continuous) AC output Power (-40 to +65C)
Peak AC output power
Output power factor
Nominal AC output voltage range
240 VAC (split phase)
208 VAC (three phase)
Maximum AC output current at nominal voltage
240 VAC (split phase)
208 VAC (three phase)
Nominal AC output frequency range
Extended AC output frequency range
Maximum AC output over current protection device
Maximum AC output fault current & duration
High AC Voltage trip limit accuracy
Low AC Voltage trip limit accuracy
Frequency trip limit accuracy
Trip time accuracy
Maximum microinverters per 20 amp AC branch circuit
240 VAC (split phase)
208 VAC (three phase)
Peak inverter efficiency
CEC weighted efficiency
Static MPPT efficiency (weighted, ref EN 50530)
Total harmonic distortion
Ambient temperature range
Night tare loss
Storage temperature range
36
AC Parameters
Miscellaneous Parameters
 2014 Enphase Energy Inc. All rights reserved.
M215 Installation and Operation
Microinverter Parameters
Unit
Min
W
W
0.95
Vrms
Vrms
Arms
Arms
Hz
59.3
Hz
A
1.05 Arms over 3 cycles
Arms/cycles
1.04 Arms over 5 cycles
2.5
%
4.0
%
Hz
±0.1
cycles
%
96.5
%
96.5
%
99.4
%
C
mW
C
Typical
Max
215
225
0.99
1
211
240
264
183
208
229
0.9
1.1
60
60.5
57
60
61
20
±2
17
25
3.0
5
-40
+65
65
-40
+65
141-00012 Rev 06