WARNING: Perform all electrical installations in accordance with all applicable local electrical
codes and the National Electrical Code (NEC), ANSI/NFPA 70.
NOTE: To ensure optimal reliability and to meet warranty requirements, the Enphase Microinverter
must be installed according to the instructions in this manual.
NOTE: The AC and DC connectors on the cabling are rated as a disconnect only when used with
an Enphase Microinverter.
NOTE: Check the labeling on the Engage Cable drop connectors to be sure that the cable matches
the electrical utility service at the site. Use 208 VAC (208 VAC three-phase) Engage Cable at sites
with three-phase 208 VAC service, or use 240 VAC Engage Cable at sites with 240 VAC single-
phase service.
NOTE: There are two release-holes in the drop connector on the cable. These are not for mounting
but are used to disconnect the connector. Keep these release holes clear and accessible.
NOTE: Protection against lightning and resulting voltage surge must be in accordance with local
standards.
NOTE: Many PV modules have a central stiffening brace. In these cases, do not position the
connector and microinverter at the exact center of the PV module. Instead, position the drop
connectors so that the connectors do not conflict with the braces.
NOTE: If you need to remove a sealing cap, you must use the Enphase disconnect tool or a #3
Phillips screwdriver. Sealing caps may not be reused.
NOTE: The M215 works with 240 VAC single-phase utility service or with 208 VAC three-phase
utility service.
NOTE: When installing the Engage Cable and accessories, adhere to the following:
NOTE: Do not use the shipping cap to cover unused connectors. The shipping cap does not
provide an adequate environmental seal. Enphase sealing caps are required to protect against
moisture ingress.
NOTE: Completely install all microinverters and all system AC connections prior to installing the PV
modules.
7
Do not expose the terminator cap or cable connections to directed, pressurized liquid
(water jets, etc.).
Do not expose the terminator cap or cable connections to continuous immersion.
Do not expose the terminator cap or cable connections to continuous tension (e.g.,
tension due to pulling or bending the cable near the connection).
Use only the connectors and cables provided.
Do not allow contamination or debris in the connectors.
Use the terminator cap and cable connections only when all parts are present and intact.
Do not install or use in potentially explosive environments.
Do not allow the terminator to come into contact with open flame.
Make sure that all terminator cap seals are seated correctly in the wire organizer.
Fit the terminator cap using only the prescribed tools and in the prescribed manner.
Use the terminator to seal the conductor end of the Engage Cable; no other method is
allowed.
 2014 Enphase Energy Inc. All rights reserved.
M215 Installation and Operation
141-00012 Rev 06