Step 7: Terminate the unused end of the cable

Terminate the unused end of the IQ Cable as follows.
A. Remove 13 mm (½ ") of the cable sheath from the
conductors. Use the terminator loop to measure 13 mm.
B. Slide the hex nut onto the cable.
C. Insert the cable into the terminator body so that each of the
two wires lands on opposite sides of the internal separator.
There is a grommet inside of the hex nut that should remain
in place.
D. Insert a screwdriver into the slot on the top of the terminator to hold it in place, and
torque the nut to 7 N m.
E. Hold the terminator body stationary with the screwdriver and turn only the hex nut to
prevent the conductors from twisting out of the separator.
NOTE: Turn only the hex nut to prevent conductors from twisting out of the
separator.
F. Attach the terminated cable end to the PV racking with
a cable clip or tie wrap so that the cable and
terminator do not touch the roof.
WARNING: The terminator cannot be re-
used. If you unscrew the nut, you must discard
the terminator.
21
IQ7/IQ7+/IQ7X/IQ7A Microinverters Installation and Operation Manual
© 2023 Enphase Energy Inc. All rights reserved.
Terminator
Body
13mm
Internal view
September 2023
IOM-00028-1.0