40
espresso coffee machines
6.5 PROGRAMMING ACCESS BLOCK
To quit programming, press and hold down the "cup warmer" for 5 seconds; in this
mode it is possible to enable the PROGRAMMING ACCESS BLOCK function.
With this function enabled, enter the programming mode with the "P" code then im-
mediately press the "cupwarmer" key and hold it down for 5 seconds to enter the
programming menu.
Otherwise the display will read "bc" for 2 seconds and then the machine will return to
the working mode.
6.6 TECHNICAL MENU
The technical menu can be used to enable or disable the E.G.S. (Electronic Ground
System) and calibrate the temperature probe.
6.7 E.G.S.
This function, which is enabled by default, makes it possible to keep the used coffee
pod moist inside the portafilter in the case it is not used for over 30 minutes.
To disable this function open the technical menu:
Press and hold down the "+" and "-" together for 15 seconds; the E.G.S. light is on.
Press the "cupwarmer" key to disable the E.G.S. function and the light will switch
off. To reactivate the function, press the "cupwarmer" button and the relevant light
will switch on.
To exit the technical menu, press and hold down the "+" and "-" keys together for 3
seconds.
Fig. 10
17
LSI 024 - Rev. 01 - Ed. 10/2016