2.
OVERVIEW
2.2.1

Overview of added functions

This section shows an overview of the added functions.
(1)
(2)
Variety of local device
(a) The device set as the local device at "Device" in Parameter can be monitored
and tested with a peripheral device.
This function allows checking and debug of the local device in the program
monitored with a peripheral device.
(b) The local device of the file where the subroutine program/interrupt program is
stored has made it possible to be used during execution of the subroutine
program/interrupt program.
For this function, even if an operation using the local device of the subroutine
program is carried out, the original local device cannot be overwritten. In
addition, even if an operation using the local device of the interrupt program, the
local device which is executed before starting up the interrupt program cannot be
overwritten.
(c) The following GPP function software packages are required to perform the
monitor test of the local device:
• Personal computer
GX Developer, SW2IVD-GPPQ type GPP function software package
Auto refresh setting of CC-Link
(a) When setting auto refresh of the CC-Link on the peripheral function, cyclic
communication with other stations connected to the CC-Link can be
automatically performed according to the set auto refresh data.
• Remote I/O station (Communication in ON/OFF data)
• Remote device station (Communication in ON/OFF data and Word data)
• Intelligent device station (Communication in ON/OFF data and Word data)
• Local station/master station (Communication in ON/OFF data and Word data)
The auto refresh setting of the CC-Link allows communication with other stations
using the FROM/TO instruction without communicating with the master station of
the CC-Link.
(b) Auto refresh is available for up to 8 CC-Link modules for each unit of QnACPU.
Communication for 9th CC-Link module and more can be performed with the
CC-Link module using the FROM/TO instruction.
(c) The following GPP function software packages are required to perform the auto
refresh setting of the CC-Link:
• Personal computer:
GX Developer, SW2IVD-GPPQ type GPP function software package
It is necessary to upgrade the master station local station module of CC-Link to
function version B or later.