Added/Changed Functions; Appendix - Mitsubishi q64rd User Manual

Rtd input module channel isolated rtd input module
Hide thumbs Also See for q64rd:
Table of Contents

Advertisement

1 OVERVIEW

1.2 Added/Changed Functions

Item
Applicable module
Online module
Function version C
change
or later
Mode
switching that
Function version C
does not
or later
require CPU to
be reset
Conversion
setting for
First 5 digits of
disconnection
product information
detection
are 07072 or later
function
First 5 digits of
Moving
product information
average
are 07072 or later
First 5 digits of
Primary delay
product information
filter
are 07072 or later
Item
Applicable version
Conversion
setting for
First 5 digits of
disconnection
product information
are 07072 or later
detection
function
1 - 4
Functions added or changed for the Q64RD/Q64RD-G are shown below.
(1) Q64RD
Functions added or changed for the Q64RD are shown below.
You can change the module without stopping the system.
The CPU of function version C or later is required.
Using the mode switching setting (buffer memory addresses 158, 159:
Un\G158, Un\G159) and operating condition setting request (Y9), the
module is switched between the normal mode and offset/gain setting
mode without the CPU being reset.
Using the dedicated instruction (G(P).OFFGAN), the module is
switched between the normal mode and offset/gain setting mode
without the CPU being reset.
Using GX Configurator-TI, the module is switched between the normal
mode and offset/gain setting mode without the CPU being reset.
For values to be stored in the CH
(buffer memory addresses 11 to 14, 54 to 61: Un\G11 to 14, Un\G54 to
61) in the case of disconnection detection, any of "Value immediately
before disconnection", "Up scale (maximum value of measured
temperature range + 5% of measured temperature range)", "Down
scale (minimum value of measured temperature range – 5% of
measured temperature range)" or "Given value" can be selected.
Digital output values sampled at specified number of times are
averaged.
By a preset time constant, digital output values are smoothed.
(2) Q64RD-G
The following is a function added for the Q64RD-G.
For values to be stored in the CH
(buffer memory addresses 11 to 14, 54 to 61: Un\G11 to 14, Un\G54 to
61) in the case of disconnection detection, any of "Value immediately
before disconnection", "Up scale (maximum value of measured
temperature range + 5% of measured temperature range)", "Down
scale (minimum value of measured temperature range – 5% of
measured temperature range)" or "Given value" can be selected.
POINT
(1) Refer to Appendix 2.1 for the function comparison between function versions.
(2) For differences between the Q64RD/Q64RD-G whose first 5 digits of product
information are 07071 or earlier and those of 07072 or later, refer to Appendix
2.2.
(3) Refer to Section 2.2 for how to check the function version and product information.
Function overview
measured temperature value
Function overview
measured temperature value
MELSEC-Q
Reference
section
Chapter 7
Section
3.4.24

Appendix

3.2
Section
5.6.2
Section
3.2.2
Section
3.2.1
Section
3.2.1
Reference
section
Section
3.2.2
1 - 4

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Q64rd-g

Table of Contents