Mitsubishi Q2ACPU User Manual page 456

Qna series melsec
Table of Contents

Advertisement

APPENDICES
(9) A to QnA conversion correspondences
ACPU
Special
Special
Special
Relay after
Relay for
Relay
Conversion
Modification
M9000
SM1000
M9002
SM1002
M9004
SM1004
M9005
SM1005
M9006
SM1006
M9007
SM1007
M9008
SM1008
SM1
M9009
SM1009
SM62
Special relays SM1000 to SM1255 are the relays which correspond to ACPU special
relays M9000 to M9255 after A to QnA conversion.
These special relays are all set by the system, and cannot be set by the user
program.
To turn them ON/OFF by the user program, change the special relays in the program
into those of QnACPU.
However, some of SM1084 and SM1200 to SM1255 (corresponding to M9084 and
M9200 to M9255 before conversion) can be turned ON/OFF by the user program, if
they could be turned ON/OFF by the user program before conversion.For details on
the ACPU special relays, see the user's manuals for the individual CPUs, and
MELSECNET or MELSECNET/B Data Link System Reference Manuals
The following are additional explanations about the Special Relay for Modification
column.
When a special relay for modification is provided, the device number should
be changed to the provided QnACPU special relay.
When
is provided, the converted special relay can be used for the device
number.
When
is provided, the device number does not work with QnACPU.
Table App. 2.10. Special relay
Name
OFF : Normal
Fuse blown
ON
I/O module verify
OFF : Normal
error
ON
NIMI link master
OFF : Normal
module error
ON
OFF : AC DOWN not
AC DOWN
––
detection
ON
OFF : Normal
Battery low
ON
OFF : Normal
Battery low latch
ON
Self-diagnosis
OFF : No error
error
ON
Annunciator
OFF : No F number detected
detection
ON
Meaning
• Turned on when there is one or more output modules of
which fuse has been blown.
• Remains ON if the condition is restored to normal
: Module with blown
thereafter.
fuse
• Output modules of remote I/O stations are also checked
fore fuse condition.
• Turned on if the status of I/O module is different form
entered status when power is turned on.
• Remains ON if the condition is restored to normal
thereafter.
: Error
• I/O module verification is done also to remote I/O station
modules.
• Reset is enabled only when special registers SD1116 to
SD1123 are reset.
• Goes ON if MINI (S3) link error is detected at even one of
the installed AJ71PT32 (S3) modules.
: Error
• Remains ON if the condition is restored to normal
thereafter.
• Turns ON if an instantaneous power failure of within 20ms
occurs during use of the AC power supply module.
• Reset when the power supply is switched OFF, then ON.
detected
• Turns ON if an instantaneous power failure of within 1ms
: AC DOWN detected
occurs during use of the DC power supply module.
• Reset when the power supply is switched OFF, then ON.
• Turns ON when the battery voltage drops to or below the
specified.
: Battery low
• Turns OFF when the battery voltage returns to normal
thereafter.
• Turns ON when the battery voltage drops to or below the
specified.
: Battery low
• Remains ON if the battery voltage returns to normal
thereafter.
• Turned on when error is found as a result of self-
: Error
diagnosis.
• Turned on when OUT F of SET F instruction is
executed.
: F number detected
• Switched off when SD1124 data is cleared to zero.
App - 59
Corresponding
Details
CPU
QnA
QnA
QnA
QnA
QnA
QnA
QnA
QnA
QnA