3.
SYSTEM CONFIGURATION
System configuration
Maximum number of
extension stages
Maximum number of I/O
modules
Maximum number of I/O
points
Main base unit model
name
Extension base unit
model name
Extension cable model
name
(1)
(2)
Precautions
(3)
(4)
(1)
(2)
I/O number assignment
(3)
(4)
(5)
(b) Q2ACPU-S1 system
Main base unit (A38B)
C
Extension
P
cable
U
A58B extension base unit
1st extension
stage
8
9
80 90
to
to to to to to to to
8F
9F
A55B extension base unit
2nd extension
stage
16 17 18 19 20 (21)(22) (23)
100
110
to
to to to to to to to
10F
11F
A68B extension base unit
3rd extension
stage
24
180
190
to
18F
19F
4th extension
stage
32
200
to
20F
It is not possible to connect an extension base unit to an A32B main base unit. For an extension base, use A32B-S1.
When using extension base units A52B, A55B, A58B, 5VDC is supplied from the power supply module of the main base.
Before use, refer to Section 17.3 and examine if it can be used.
The overall distance of the extension cable must be 6.6m (21.65ft.) or shorter.
When using the extension cable, do not tie it with the main circuit cables, which has high voltage, large current, or install
them close to each other.
I/O numbers are allocated in accordance with the order of the numbers set for the extension base stages, regardless of
the order in which the extension cables are connected.
Assign I/O numbers as if both main base unit and extension base unit have 8 slots each.
Consequently, allocations of 16 points per slot are made for the parts of the system configuration drawing indicated with
dotted lines.
16 points are assigned to an empty slot.
Extension stage numbers do not need to be sequential, but any extension stage omitted from the system will occupy 8
(slots) 16 I/O points.
With regard to items (2) to (4) above, the I/O allocations can be changed by setting I/O allocations in the
parameters.(Refer to Section 5.3)
0
2
3
Slot No.
1
4
5
6
7
00 10 20 30 40 50 60 70
to
to to to to to to to
0F 1F 2F 3F 4F 5F 6F 7F
* An example when the 16-point module
10
11 12 13 14 15
A0
B0
C0
D0
E0
F0
AF
BF
CF
DF
EF
FF
5th extension
stage
120
130
140
150
160
170
14F
16F
17F
12F
13F
15F
6th extension
stage
25
26
27
28
29
30
31
1A0
1B0
1C0
1D0
1E0
1F0
to to to to to to to
1AF
1BF
1CF
1DF
1EF
1FF
7th extension
stage
33
34
35
36
37
38
39
210
220
230
240
250
260
270
to to to to to to to
21F
22F
23F
24F
25F
26F
27F
7th extension stage
64 modules
1024 points
A32B, A32B-S1, A35B, A38B, A38HB, A38HBEU
A62B, A65B, A68B, A52B, A55B, A58B
AC06B, AC12B, AC30B
3 - 4
is installed to each slot is shown.
A65B extension base unit
(45)(46)
40
41
42
43
44
280
290
2A0
2B0
2C0
2D0
2E0
to
to to to to to to to
28F
29F
2AF
2BF
2CF
2DF
2EF
48
49
50
51
52
53
300
310
320
330
340
350
360
to
to to to to to to to
30F
31F
32F
33F
34F
35F
36F
56
57
58
59
60
61
380
390
3A0
3B0
3C0
3D0
3E0
to
to to to to to to to
38F
39F
3AF
3BF
3CF
3DF
3EF
(47)
2F0
2FF
54
55
370
37F
62
63
3F0
3FF

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q3acpuQ4acpuQ2acpus1