3.
SYSTEM CONFIGURATION
System configuration
Maximum number of
extension stages
Maximum number of I/O
modules
Maximum number of I/O
points
Main base unit model
name
Extension base unit
model name
Extension cable model
name
(1)
(2)
Precautions
(3)
(4)
(1)
(2)
I/O number assignment
(3)
(4)
(5)
(c) Q3A/Q4ACPU system
Main base unit (A38B)
C
Extension
P
cable
U
A58B extension base unit
1st extension
stage
8
9
80 90
to to to to
8F
9F
A55B extension base unit
2nd extension
stage
16 17 18 19 20 (21)(22) (23)
100
110
to to to to
10F
11F
A68B extension base unit
3rd extension
stage
24
180
to to to to
18F
4th extension
stage
32
200
to to to to
20F
It is not possible to connect an extension base unit to an A32B main base unit. For an extension base, use A32B-S1.
When extension base unit A52B, A55B, A58B is used, 5VDC power supply is supplied from the power supply module of
the main base. Before use, refer to Section 17.3 and examine if it can be used.
The overall distance of the extension cable must be 6.6m (21.65ft.) or shorter.
When using the extension cable, do not tie it with the main circuit cables, which has high voltage, large current, or install
them close to each other.
I/O numbers are allocated in accordance with the order of the numbers set for the extension base stages, regardless of
the order in which the extension cables are connected.
Assign I/O numbers as if both main base unit and extension base unit have 8 slots each.
Consequently, allocations of 16 points per slot are made for the parts of the system configuration drawing indicated with
dotted lines.
16 points are assigned to an empty slot.
Extension stage numbers do not need to be sequential, but any extension stage omitted from the system will occupy 8
(slots) 16 I/O points.
With regard to items (2) to (4) above, the I/O assignment can be changed by setting I/O assignments in the
parameters.(Refer to Section 5.3)
0
1
2
3
4
5
6
7
00 10 20 30 40 50 60 70
to to to to
to to to
to
0F 1F 2F 3F 4F 5F 6F 7F
* An example when the 16-point module
10
11 12 13 14 15
A0
B0
C0
D0
E0
F0
to to to
to
AF
BF
CF
DF
EF
FF
5th extension
stage
120
130
140
150
160
170
to to to
to
12F
13F
14F
15F
16F
17F
6th extension
stage
25
26
27
28
29
30
31
190
1A0
1B0
1C0
1D0
1E0
1F0
to to to
to
19F
1AF
1BF
1CF
1DF
1EF
1FF
7th extension
stage
35
33
34
36
37
38
39
250
210
220
230
240
260
270
to to to
to
21F
22F
23F
24F
25F
26F
27F
7th extension stage
64 modules
Q3A
2048 points/Q4A
4096 points
A32B, A35B, A38B, A38HB, A38HBEU
A62B, A65B, A68B, A52B, A55B, A58B
AC06B, AC12B, AC30B
3 - 5
Slot No.
is installed to each slot is shown.
A65B extension base unit
(45)(46)
40
41
42
43
44
280
290
2B0
2C0
2A0
2D0
to to to to
to to to
29F
2AF
2BF
2CF
28F
2DF
48
49
50
51
52
53
300
310
320
330
340
350
to to to to
to to to
30F
31F
32F
33F
34F
35F
56
57
58
59
60
61
380
390
3A0
3B0
3C0
3D0
to to to to
to to to
38F
39F
3AF
3BF
3CF
3DF
(47)
2E0
2F0
to
2EF
2FF
54
55
360
370
to
36F
37F
62
63
3E0
3F0
to
3EF
3FF

Advertisement