Mitsubishi Q2ACPU User Manual page 502

Qna series melsec
Table of Contents

Advertisement

APPENDICES
Special
ACPU
Special
Register
Special
Register for
after
Register
Modification
Conversion
D9248
SD1248
D9249
SD1249
D9250
SD1250
D9251
SD1251
D9252
SD1252
D9253
SD1253
D9254
SD1254
D9255
SD1255
(11)Fuse blown module
Number
Name
Meaning
SD1300
SD1301
SD1302
SD1303
Bit pattern in units
SD1304
of 16 points,
indicating the
SD1305
Fuse blown
modules whose
SD1306
module
fuses have blown
SD1307
0 : No blown fuse
1 : Blown fuse
SD1308
present
SD1309
to
SD1330
SD1331
Table App. 3.11. Special register
Name
Meaning
Local station
Stores conditions for
up to numbers 1 to 16 Stores the local station number which is in STOP or PAUSE mode.
operation status
Stores conditions for
Local station
up to numbers 17 to
operation status
32
Stores conditions for
Local station
up to numbers 33 to
operation status
48
Stores conditions for
Local station
up to numbers 49 to
operation status
64
Local station
Stores conditions for
error conditions
up to numbers 1 to 16
Stores conditions for
Local station
up to numbers 17 to
error conditions
32
Stores conditions for
Local station
up to numbers 33 to
error conditions
48
Stores conditions for
Local station
up to numbers 49 to
error conditions
64
Table App. 3.12. Special register
• The numbers of output modules whose fuses have blown are input as a
bit pattern (in units of 16 points).
(If the module numbers are set by parameter, the parameter-set
numbers are stored.)
• Also detects blown fuse condition at remote station output modules
b15 b14 b13 b12 b11b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
1
0
0
0
0
SD1300
(YC0)
1
0
0
0
0
SD1301
(Y1F0)
1
0
0
0
0
Y1F
SD1331
B0
• Not cleared even if the blown fuse is replaced with a new one.
This flag is cleared by error resetting operation.
Device
number
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SD1248
L16 L15 L14 L13 L12 L11
SD1249
L32 L31 L30 L29 L28 L27
SD1250
L48 L47 L46 L45 L44 L43
SD1251
L64 L63 L62 L61 L60 L59
The bit corresponding to the station number which is in STOP or
PAUSE mode, becomes "1".
Example: When local stations 7 and 15 are in STOP mode, b6 and
b14 of SD1248 become "1", and when SD1248 is
monitored, its value is "16448 (4040H)".
Stores the local station number other than the host, which is in error.
Device
number
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SD1252
L16 L15 L14 L13 L12 L11
SD1253
L32 L31 L30 L29 L28 L27
SD1254
L48 L47 L46 L45 L44 L43
SD1255
L64 L63 L62 L61 L60 L59
The bit corresponding to the station number which is in error,
becomes "1".
Example: When local station 12 is in error, b11 of SD1252 becomes
"1", and when SD1252 is monitored, its value is "2048
(800H) ".
Explanation
1
0
0
0
0
0
0
0
0
0
(Y80)
1
0
0
0
0
0
0
0
0
0
(Y1A0)
1
0
0
0
0
0
0
0
Y1F
0
0
30
Indicates fuse blow.
App - 105
Details
Bit
L10 L9 L8 L7 L6 L5 L4 L3 L2 L1
L26
L25
L24
L23
L22
L21
L20
L19
L18
L17
L42
L41
L40
L39
L38
L37
L36
L35
L34
L33
L58
L57
L56
L55
L54
L53
L52
L51
L50
L49
Bit
L10 L9 L8 L7 L6 L5 L4 L3 L2 L1
L26
L25
L24
L23
L22
L21
L20
L19
L18
L17
L42
L41
L40
L39
L38
L37
L36
L35
L34
L33
L58
L57
L56
L55
L54
L53
L52
L51
L50
L49
Corres-
ponding
Set by
ACPU
(When Set)
D9
D9100
D9101
D9102
D9103
D9104
D9105
0
S (Error)
D9106
0
D9107
New
0
New
New
Corresponding
CPU
QnA
QnA
Corresponding
CPU
QnA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q3acpuQ4acpuQ2acpus1

Table of Contents