Allen-Bradley PanelView 800 2711R-T4T User Manual page 92

Panelview 800 series hmi terminals
Table of Contents

Advertisement

Chapter 6
Virtual Network Computing
92
VNC Settings
Setting
(1)
Access
View-Only Password
Control Password
(1)
It is recommended to enable only the view-only access to the terminal. Enabling control access increases the
security risk if the password is compromised.
(2)
Once a password is set, you can only change it. You cannot clear a password unless you perform a restore
operation or return the terminal to the out-of-box condition. See
112
and
Restoring the Terminalon page 113
Changing any VNC setting will terminate the current VNC
IMPORTANT
connection to the terminal. For example, if you are connected to
the terminal in control access and change the access to
view-only, the VNC connection will terminate and the next time
you connect to the terminal you will be in view-only access.
When you update the terminal firmware, the VNC password
IMPORTANT
and settings will be cleared and reset to their default
configuration.
Set the Password for VNC Connection
The default VNC settings (no password) prevents you from establishing a VNC
connection to the terminal. You must set a view-only or control access password
before you can connect to the terminal with the respective access rights.
Follow these steps to set a password for VNC connection to the terminal.
1. Press Enable/Disable to enable the VNC server.
Rockwell Automation Publication 2711R-UM001E-EN-E - January 2017
Description
Switch between view-only and control access
for the VNC connection to the terminal.
View-Only – No interaction allowed. Only the
current screen on the terminal is displayed.
Control – Interaction allowed.
Resets the current password a user must
enter when establishing a VNC connection to
the terminal for view-only access.
The password is a maximum of seven
alphanumeric characters (A...Z, a...z, 0...9).
Resets the current password a user must
enter when establishing a VNC connection to
the terminal for control access.
The password is a maximum of seven
alphanumeric characters (A...Z, a...z, 0...9) and
special characters ('_', '$', '-', and '!'). A
minimum of one special character is required
for the control access password.
Returning to the Out-of-box Condition on page
for instructions.
Default
View-Only
(2)
No password
(2)
No password