Appendix D
Configure Security
User Accounts Screen
Setting
Idle Time Out Length
Mask Password Entry
Password & User Name Type
Design Environment Secured
134
Description
Adjust or disable the idle timeout by selecting the value from the drop-down list. If disabled, the
application will not transition from a secured screen to the startup screen.
The default idle timeout is 15 minutes. If the terminal receives no user input within that 15 minute
period, it goes into Idle mode. User input includes key presses, touch-screen presses, external mouse
or keyboard input.
If the terminal goes into idle mode, the application transitions from a secured screen to the startup
screen. The screen does not change if the current screen is unsecured. The current user is logged out
and the user must log in again.
Masks a password with a character when it is entered so that it is not visible. To disable this feature,
set the option to False. Disabling this feature is not recommended.
By default, user names and passwords are entered using an alphanumeric keypad at runtime. To use a
numeric keypad, set the option to Numeric Keypad.
Using a numeric keypad requires numeric user names and passwords.
Protects the application by preventing unauthorized access to edit/modify/update an application by
users without the proper rights. Create user accounts and assign rights for them to perform these
actions. Design rights allow users to update the application, and access rights allow users to view
certain screens on the terminal at runtime.