Allen-Bradley PanelView 800 2711R-T4T User Manual page 39

Panelview 800 series hmi terminals
Table of Contents

Advertisement

2. Press File Manager.
Source:
Internal
PVcApplication1
Recipe
Copy Alarm History
Startup Application
IMPORTANT
3. Select Internal from the Source list.
4. Select the name of the startup application from the Name list.
5. Click Set As Startup.
Change the Date and Time
You can adjust the current date and time for terminal operations. The time is set
in 24-hour format. If using PanelView Explorer, you can also set the terminal to
automatically adjust the time for daylight savings time.
Follow these steps to change the terminal date and time using PanelView
(1)
Explorer.
1. Go to the PanelView Explorer Startup window.
2. Click the Terminal Settings link.
3. Click the System Information tab.
4. Update the Current date fields.
5. Update the Current time fields.
(1)
The PanelView Explorer feature is not supported on PanelView 800 terminals from firmware revision 3.011
onwards.
Rockwell Automation Publication 2711R-UM001E-EN-E - January 2017
File Manager
To:
Internal
Controller Settings
The Stop Application button is only available in firmware
revision 3.011 onwards.
Configuration Mode
Chapter 2
Copy
Delete
Set As Startup
Run
Stop Application
Reset
Main
39