Hour Meter - JVC GY-DV5000U Service Manual

Hide thumbs Also See for GY-DV5000U:
Table of Contents

Advertisement

ERROR RATE MONITOR screen
By setting "DIP SW 0" to "1", error rate and each CPU port infor-
mation display screen will appair on the LCD monitor, View finder
and monitor.
The values which are pointed by arrow are the error rate value.
Error rate of CH-1 shown in upper row, and ch-2 shown in lower
row, and these value are indicated total AUDIO/VIDEO error rate.
When the error rate increase , the warning message "HEAD
CLEANING REQUIRED" is displayed. And this massage is indi-
cate when the error rate value is over 4,500 (one-channel AU-
DIO/VIDEO total) for 7 seconds consecutively.
ERROR RATE indicator
XXXX
XX
65535
XX
XX
65535
XX
XX
F I L 1
XX
XX
T
CH
F 5. 6 8
D
XX
CH
S T B Y
0 1 / 0 2 / 0 3 AM0 1 : 2 3 : 4 5

1.9.10 HOUR METER

In a service menu, place the cursor on "HOUR METER " and
push the SHUTTER dial to display the HOUR METER menu.
– – – H O U R M E T E R [ 1 / 2 ] – – –
D R UM
T O T A L D R UM
P OW E R
C A P S T A N
R E E L
F W D
R E E L
F W D
N E X T P A G E
P A G E B A C K
Fig. 1-9-12 (1)
– – – H O U R M E T E R [ 2 / 2 ] – – –
L O A D I N G
E J E C T ( M I N I )
E J E C T ( S T D )
F W D / R E V
F F / R E W
C L A E N E R
P A G E B A C K
Fig.1-9-12 (2)
1-12
0 0 : 0 0 : 0 0 : 0 0
XX
XX
SP 2 0 mir
A D P
F A S
-3 d B
XX
F A W
XX
XX
XX
XX
I
XX
XX
XX
XX
SD
XX
XXXX
B
1
--
--
-+
--
1 2 . 2 V
2
--
--
-+
--
C L E A R
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
C L E A R
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
Operation ways are almost same as CAMERA 1 menu, so please
refer it
Item
DRUM
000000 Displays the drum hour
meter(maintenance for drum)
CLEAR Deletes the drum hour meter.
000000 Displays the total hour meter.
TOTAL DRUM
CLEAR Deletes the total hour meter.
(This does not work unless the special
setting)
POWER
000000 Displays the power hour meter.
CLEAR Deletes the power hour meter.
000000 Displays the capstan hour meter.
CAPSTAN
CLEAR Deletes the capstan hour meter.
000000 Displays the reel forward hour meter.
REEL FWD
CLEAR Deletes the reel forward hour meter.
000000 Displays the reel reverse hour meter.
REEL REV
CLEAR Deletes the reel reverse hour meter.
000000 Displays the loading count.
LOADING
CLEAR Deletes the loading count.
000000 Displays the eject count for mini
EJECT (MINI)
cassette.
CLEAR Deletes the eject count for mini
cassette.
EJECT (STD)
000000 Displays the eject count for standard
cassette.
CLEAR Deletes the eject count for standard
cassette.
FWD/REV
000000 Displays the forward/reverse
switching count.
CLEAR Deletes the forward/reverse switching
count.
FF/REW
000000 Displays the FF/REW switching
count.
CLEAR Deletes the FF/REW switching count
000000 Displays the cleaner working count.
CLEANER
CLEAR Deletes the Cleaner working count.
Table 1-9-10