JVC GY-DV5000U Service Manual page 18

Hide thumbs Also See for GY-DV5000U:
Table of Contents

Advertisement

Item
P.TM
POWER HOUR METER
SYS MODE
SYSCON CPU mode when error occurred
MSD MODE
MSD CPU mode and target mode when
error occurred
LAST KEY
Final Key code when error occurred
TAPE REM
TAPE REMAIN
DEW
DEW sensor A/D intake value
TEMP
Temperature sensor A/D intake value
The value "49" [5°C] is threshold of
detecting low temperture. The value "DC"
[60°C] is the threshold of displaying "OVER
HEATING" message.
DIAMETER
Displays wound tape diameter (Take-up, Supply)
M. POSI
Mechanism position and target mechanism
position
H. POSI
Housing position and target housing position
CAP
Capstan status
REL
Reel status
DRM
Drum status
Direction of tape running (Direction of target)
DIR
DRV
Drum control voltage
CAPV
Capstan control voltage
RELV
Reel control torque value
1-14
Content
PLAY (03, 00)
MODE DATA
Parameter
PLAY (01, 00)
MODE DATA
Parameter
PLAY (E7, 01)
MODE DATA
Parameter
Displayed Content
Power hour meter is display.
SFF/SREW parameter is speed display.
(Refer to Table 1-9-11 (2) Speed parameter)
Parameters of other modes are irrelevant.
EJECT (01) : Eject
STOP (02) : Stop
PLAY (03)
: Play
STL (04)
: Still
FF (05)
: FF
REW (06)
: Rew
SFF (07)
: Search Fwd
SREW (08) : Search Rev
SFF/SREW parameter is speed display (See Table 1-9-11 (2))
Other parameters are 01: ON, 00: OFF
REC (E0)
: Rec
RECP (E1) : Rec Pause
DVRP (E2) : DV Rec Pause
ADUB (E5) : Audio Dub
ADBP (E6) : Audio Dub Pause HWUP (F2) : Housing Up
PLAY (E7)
: Play
STL (E8)
: Still
FF (E9)
: FF
REW (EA)
: Rew
Displays tape remaining in minutes ([FFFF] : not detected)
DEW display at over [48]
Temperature is displayed in hexadecimal value.
-10°C a [22]
20°C a [7C]
- 5°C a [2D] 25°C a [8C]
0°C a [3A]
30°C a [9C]
5°C a [49]
35°C a [AA]
10°C a [59]
40°C a [B7]
15°C a [6A]
45°C a [C2]
[00]—[FF] : 0mm-82mm (Diameter) ([00] is non-detected)
[2ULD], [ULD2BRK], [BRK], [BRK2FAST], [FAST], [FAST2STP],
[STP], [STP2SRH], [SRH], [SRH2], [INIT] ("2" is the meaning of "To".
It means transition. Refer to section 2, Mechanism Timing Chart)
[EJECT], [EJECT2IN], [CASS IN], [RELEASE](Release the
SUP reel lock.)
[INIT](For the intake and eject operation, refer to section 8.2.3.)
[ON]
: Rotate
[OFF]
: Stop
[ON]
: Rotate
[OFF]
: Stop
[ON]
: Rotate
[OFF]
: Stop
[FWD/REV]: Direction display
[00-FF]
: 0—3V
[00-FF]
: 0—3V
[00-FF]
: 0—3A
ADUB (0B) : Audio Dub
ADBP (0C) : Audio Dub Pause
REC (13)
: Rec
RECP (14) : Rec Pause
DVRC (15) : DV Rec
DVRP (16) : DV Rec Pause
POFF (1A) : Power Off
NDEF (1F) : During initial operation
SFF (EB)
: Search Fwd
SREW (EC) : Search Rev
STOP (F0) : Stop
EJECT (F1) : Eject
HWDN (F3) : Housing Down
POFF (F4) : Power Off
DVRC (F5) : DV Rec
PON (FA)
: Power on
50°C a [CC]
55°C a [D4]
60°C a [DC]
"OVER HEATING" message
65°C a [E1]
70°C a [E6]
[FWD/REV]: Direction display
[FWD/REV]: Direction display

Hide quick links: