Item
MCV/SPD
Loading/cassette housing control voltage
(when error code 4xxx and error code 3xxx
is displayed.)
Tape speed (When the code excepting
error code 4xxx and error code 3xxx is
displayed.)
RELI
Reel current (Cassette housing motor current
only during housing-related warning)
BGN
Begin sensor
END
End sensor
CAS
Cassette SW status
STD
Standard cassette SW status
HW, HW2
Housing SW/Housing 2SW status
SPL
SUP Lock SW status (during loading)
THIN
Thin tape detection
Content
Table 1-9-11 (1) MECHANISM INFO content
Parameter
Speed
00
x 0
1F
x 0.03
40
x 0.10
53
x 0.20
61
x 0.30
6D
x 0.50
7A
x 0.80
7B
x 0.84
7D
x 0.90
7F
x 0.96
80
x 1.00
81
x 1.04
Table 1-9-11 (2) Speed parameter
Displayed Content
[00-FF] : 0—8V
(Displays mode motor control voltage
during error code 3xxx)
(Displays cassette motor control voltage
during error code 4xxx)
[00-FA] : 0—25X
(FF is displayed when the speed is faster
than this.)
"Tape speed" is a function to convert the
hexadecimal value into a decimal value,
and no speed parameter of the tape.
(ex. FAh = 250 → The speed is 25.0X.)
[00-FF] : 0—1.2A
[ON]
: Leader tape detected
[OFF] : Magnetic tape detected
[ON]
: Trailer tape detected
[OFF] : Magnetic tape detected
[ON]
: No cassette
[OFF] : Cassette detected (STD/MINI)
[ON]
: Mini cassette tape inserted
[OFF] : STD cassette tape inserted
HW SW
HW2 SW
a
[ON]
[OFF]
a
[OFF]
[ON]
a
[ON]
[ON]
a
[OFF]
[OFF]
[ON]
: Normal operation (TU side tape winding)
[OFF] : Lock release
(Tape begin detected, Supply side tape winding mode)
[ON]
: THIN
[OFF] : NORMAL
Parameter
Speed
82
x 1.08
83
x 1.11
84
x 1.12
85
x 1.16
91
x 2.00
A9
x 5.00
BD
x 9.00
C0
x 10.0
C4
x 12.0
CC
x 15.0
D3
x 20.0
Housing status
0
EJECT Initial position
Cassette intake
Ejecting Mini cassette