Measuring
No.
Item
instruments &
Input signals
– – – A D J U S T M E N U – – –
1 0 0 . P B
S W
V R D A T A
:
C T L D A T A
:
S E T D A T A
:
D A T A
:
0 0 0 0 0 0 0 0
2
ME recording
current
adjustment
– – – A D J U S T M E N U – – –
1 0 5 . M E
R E C C U R R E N T
V R D A T A
:
C T L O U T
:
S E T D A T A
:
C H 1
6 5 5 3 5
C H 2
6 5 5 3 5
Recording the current adjustment
Measuring point ( * )
Adjustment parts ( - )
Mode
Adjustment level ( + )
P O I N T
- - - -
1 2 0
1 2 0
Rotate the SHUTTER dial to
display data.
After displaying the data, press
the SHUTTER dial to complete
the adjustment.
* MONITOR LCD
• REC
- SHUTTER dial
• ADJUST
+ SET DATA = 115
MENU, 105.
ME REC
CURRENT
1 1 5
1 1 5
1 1 5
Adjustment procedure
(4) Measure TP6 (SPA) by triggering TP5 (HID) and
confirm that the values a and b are within the
specified ranges.
(5) Rotate the SHUTTER dial to display the adjust-
ment data in the "DATA:" field. (The DATA value
should not be 00000000 or FFFFFFFF.)
(6) Press the [SET] button so that the * marking
stops blinking. Now the adjustment is com-
plete.
NOTE:
Make sure that the data value is displayed
before pressing the SHUTTER dial. If this
adjustment is completed before the data
value is displayed the adjustment value will
not be put into the memory.
(1) Press the EDIT SEARCH +/– button to select
ADJUST MENU No. 105, "ME REC CURRENT"
and enter REC mode.
(2) Check the set data so that the value is "115"
(Recording current is approx. 360 mVp-p). If
not, adjust the value to "115"
(3) Press the SHUTTER dial to store the adjust-
ment data.